Skip to content

Need stainless steel fittings, valves or hose?

Dash Numbers on Drawings: Reading -4 to -32 Without a Chart

Dash numbers decoded: dash ÷ 16 = inches, -6 is 3/8 inch tube OD not pipe size, the SAE J514 lineage, and the metric-twin trap.

May 24, 2027 · 5 min read · FerruleX Factory

Small stainless union fitting in the dash-sized tube range

Dash numbers are the shorthand every fitting drawing speaks and every first-time buyer mistranslates.

The dash decodes with one rule: divide by sixteen. -4 is 4/16 inch, -6 is 6/16 inch, -8 is 8/16 inch, and a callout that says nothing about threads is giving you a size, not a connection type.

On tube and JIC fittings that figure is the tube outside diameter. It is not a pipe size and it is not a millimetre size. Both traps cost orders, and both are avoidable with one measurement at the bench.

Key takeaways

  • The rule: dash ÷ 16 = nominal size in inches. -6 is 6/16 = 3/8 inch; -8 is 8/16 = 1/2 inch.
  • On tube and JIC fittings the dash is the tube OUTSIDE diameter; -8 means 1/2 inch OD tube.
  • Dash is not NPS: 1/2 NPS pipe has a 0.840 in OD — the -8 tube beside it is 12.7 mm. Different numbering systems entirely.
  • Dash sizing descends from AN/aerospace practice, standardized industrially as SAE J514 37° flare.
  • The metric twin is a convention, not an equivalence: -6 pairs with 10 mm in catalogs, but the tubes are 9.53 and 10.0 mm — not interchangeable.

Which number is the drawing asking for?

Four callout families share a vocabulary of halves and quarters: the inch dash, the hose dash, NPS pipe, and the ISO metric pipe name. Only one of them measures a tube, and the drawing rarely says which one it used.

What the drawing says What the number denotes What decides it
-4, -6, -8, -12 on a tube or JIC fitting Tube outside diameter in sixteenths: 6.35, 9.53, 12.70, 19.05 mm Measure the tube OD; the dash must match the sleeve, not the catalog column
-6, -8 on a hose end Hose inside diameter, not outside diameter Read whether the line says hose or tube — the dash convention flips
1/2 NPS A pipe name, not a measurement; actual OD fixed at 0.840 in (21.3 mm) Pipe OD is set by the pipe standard regardless of wall
DN 15 ISO metric pipe name approximating NPS × 25 It is a pipe name and maps to the same 21.3 mm OD pipe
-6 listed beside 10 mm A catalog pairing by convention, not an equivalence 3/8 inch is 9.53 mm, not 10 — order to the measured tube
-4 NPT Two numbering systems in one callout Bench thread check before anything else
-30 on a metric-based dash callout A 30 mm reference, not 30/16 inch Check whether the drawing is metric-based before dividing

The decisive column is the measurement, not the label. Put a -8 union and a 1/2 NPT half-coupling side by side and the pipe is 68% larger in outside diameter — they do not meet, and no adapter improvises it.

Two nuances ride along with the dash on hose. On hose ends the dash usually denotes hose inside diameter, not OD; and the SAE 100R5 hose type is the documented exception where dash equals a tube OD. Neither changes the tube rule; both change what you order for hose.

The dash itself is a child of American military aviation. Air Force-Navy (AN) aeronautical standards sized hoses and fittings in sixteenths, the Joint Industries Council carried the practice into industrial hydraulics, and SAE standardized it as J514 — the 37° flare system the trade calls JIC.

That lineage explains the boundary. Dash sizing belongs to the flare-tube world, not to pipe threads, which follow their own charts and conventions. When a drawing mixes the two — a port called -4 NPT — read it with suspicion and check the thread itself; the 5-minute bench identification settles which thread you are holding. Mixing the systems is a documented way to order the wrong part.

What does the dash decode to?

Arithmetic, no lookup: dash ÷ 16 = nominal size in inches. -12 is three-quarters, -16 is one inch, and the series runs past -32 for large-bore hose.

Our printable dash size chart maps the full -4 to -32 range to fractional inch and millimetres. Keep it at the desk; the rule is for the field, when the chart is not.

Dash Fractional inch mm Typical use
-4 1/4 6.35 Small instrument and pilot lines
-6 3/8 9.53 Workhorse instrument tube size
-8 1/2 12.70 Instrument and hydraulic mains
-10 5/8 15.88 Medium hydraulic lines
-12 3/4 19.05 Process and hydraulic distribution
-14 7/8 22.23 Less common; larger instrument runs
-16 1 25.40 Hydraulic supply and return lines
-20 1-1/4 31.75 Larger hydraulic and process runs
-24 1-1/2 38.10 Manifold and station feeds
-28 1-3/4 44.45 Rare; special machinery runs
-32 2 50.80 Large-bore hose and tube headers

Full printable version: dash size chart

Is -6 the same as 10 mm?

No. The dash is a sixteenths code and the metric column is a metric tube size; catalogs pair them by convention, not by equivalence. -6 sits beside 10 mm, -8 beside 12 mm, -4 beside 6 mm.

The gap is small and fatal: 3/8 inch is 9.53 mm, not 10; 1/2 inch is 12.7 mm, not 12. The sleeve or ferrule has to grip the actual tube, so a -6 fitting on 10 mm tube is a leak waiting for its shift.

The metric-versus-fractional division of the tube world is worked through in metric vs fractional tube sizes. One more wrinkle for international drawings: metric-based dash callouts drop the millimetre number itself, so a -30 thread is a 30 mm reference, not 30/16 inch.

How do you check a dash callout at the bench?

Five steps and one caliper. Do this before the RFQ leaves your desk, not after the parts arrive.

  1. Read the callout exactly as drawn: -4, -6, -8, -12. Not the catalog description of the part someone quoted you.
  2. Decide what the line is — tube, hose, or pipe. On hose the dash is bore ID; on tube it is outside diameter.
  3. Measure the tube OD. 9.53 mm is -6, 12.70 mm is -8; a 10 mm tube is neither and must not take either fitting.
  4. Check the port thread whenever the callout mixes systems, as in -4 NPT. A thread check costs minutes; a wrong order costs a return.
  5. Confirm the sleeve or ferrule matches that measured OD. Record wall or schedule separately — the dash says diameter, not wall.

What goes wrong, and what to change

Symptom Most likely cause What to change
Fitting will not seal on a 10 mm tube A -6 fitting taken from the metric column; the tube is 10.0 mm, the dash 9.53 mm Order to the measured tube OD, not the neighbouring column
Nut tightens but the joint still moves or weeps Ferrule sized from the dash label rather than the tube it has to grip Match the sleeve to the measured OD
A -8 union will not meet a 1/2 NPT half-coupling Dash is tube OD at 12.7 mm; NPS 1/2 pipe is fixed at 0.840 in (21.3 mm) OD Identify the system before ordering; no adapter bridges it
Hose assembly arrives with the wrong bore Dash read as outside diameter; on hose ends it usually means inside diameter Read whether the line is hose or tube
-4 NPT on the drawing, nothing fits Two numbering systems written into one callout Bench thread check first, quotation second
Part arrives for a 30 mm metric tube A metric-based dash callout divided by sixteen Check whether the callout is metric-based before dividing

Every row ends in the same place: the number on the drawing describes a diameter in one specific system. The measurement decides, and the measurement is taken on the part in front of you.

What goes on the RFQ?

  • dash size as drawn — copy the callout exactly: -6, -8.
  • actual tube OD — in inches or millimetres, whichever the shop measures.
  • system — JIC 37° flare, SAE, or metric tube; the fitting body must match.
  • hose or tube — the dash convention flips between the two.
  • thread check — where an NPS or NPT callout sits beside a dash.
  • wall or schedule — dash says diameter, not wall.

Those six lines answer the questions a quotation desk would otherwise ask by email.

FAQ

Is -8 the same as 1/2 inch?

As a tube size, yes: 8/16 = 1/2 inch tube OD. As a pipe size, no: 1/2 NPS pipe has a fixed 0.840 in (21.3 mm) OD. Different codes, different diameters.

Does -6 mean 6 mm?

No. -6 is 6/16 inch = 3/8 inch = 9.53 mm. The catalog pairing with 10 mm tube is convention, not equivalence — a 0.47 mm difference the gripping hardware cannot forgive.

What does the dash mean on a hose fitting?

On hose ends the dash commonly denotes hose inside diameter: -6 hose has a 3/8 inch bore. Tube fittings use the opposite convention, dash equals tube OD. SAE 100R5 hose is the documented exception, where dash equals a tube OD.

Is dash sizing the same as NPT?

No. Dash descends from the AN/SAE J514 37° flare tube system; NPT is the ASME tapered pipe-thread system, with size names that match no measured diameter. A drawing mixing them needs a thread check before a quote.

Where does the dash system come from?

American military aviation: Air Force-Navy standards sized lines in sixteenths, the Joint Industries Council carried that into industry, and SAE standardized it as J514 — the 37° flare system known as JIC. Aviation plumbed with tube, not pipe.

Related articles

More guides for stainless steel fittings buyers.