Dash numbers are the shorthand every fitting drawing speaks and every first-time buyer mistranslates.
The dash decodes with one rule: divide by sixteen. -4 is 4/16 inch, -6 is 6/16 inch, -8 is 8/16 inch, and a callout that says nothing about threads is giving you a size, not a connection type.
On tube and JIC fittings that figure is the tube outside diameter. It is not a pipe size and it is not a millimetre size. Both traps cost orders, and both are avoidable with one measurement at the bench.
Key takeaways
- The rule: dash ÷ 16 = nominal size in inches. -6 is 6/16 = 3/8 inch; -8 is 8/16 = 1/2 inch.
- On tube and JIC fittings the dash is the tube OUTSIDE diameter; -8 means 1/2 inch OD tube.
- Dash is not NPS: 1/2 NPS pipe has a 0.840 in OD — the -8 tube beside it is 12.7 mm. Different numbering systems entirely.
- Dash sizing descends from AN/aerospace practice, standardized industrially as SAE J514 37° flare.
- The metric twin is a convention, not an equivalence: -6 pairs with 10 mm in catalogs, but the tubes are 9.53 and 10.0 mm — not interchangeable.
Which number is the drawing asking for?
Four callout families share a vocabulary of halves and quarters: the inch dash, the hose dash, NPS pipe, and the ISO metric pipe name. Only one of them measures a tube, and the drawing rarely says which one it used.
| What the drawing says | What the number denotes | What decides it |
|---|---|---|
-4, -6, -8, -12 on a tube or JIC fitting |
Tube outside diameter in sixteenths: 6.35, 9.53, 12.70, 19.05 mm | Measure the tube OD; the dash must match the sleeve, not the catalog column |
-6, -8 on a hose end |
Hose inside diameter, not outside diameter | Read whether the line says hose or tube — the dash convention flips |
1/2 NPS |
A pipe name, not a measurement; actual OD fixed at 0.840 in (21.3 mm) | Pipe OD is set by the pipe standard regardless of wall |
DN 15 |
ISO metric pipe name approximating NPS × 25 | It is a pipe name and maps to the same 21.3 mm OD pipe |
-6 listed beside 10 mm |
A catalog pairing by convention, not an equivalence | 3/8 inch is 9.53 mm, not 10 — order to the measured tube |
-4 NPT |
Two numbering systems in one callout | Bench thread check before anything else |
-30 on a metric-based dash callout |
A 30 mm reference, not 30/16 inch | Check whether the drawing is metric-based before dividing |
The decisive column is the measurement, not the label. Put a -8 union and a 1/2 NPT half-coupling side by side and the pipe is 68% larger in outside diameter — they do not meet, and no adapter improvises it.
Two nuances ride along with the dash on hose. On hose ends the dash usually denotes hose inside diameter, not OD; and the SAE 100R5 hose type is the documented exception where dash equals a tube OD. Neither changes the tube rule; both change what you order for hose.
The dash itself is a child of American military aviation. Air Force-Navy (AN) aeronautical standards sized hoses and fittings in sixteenths, the Joint Industries Council carried the practice into industrial hydraulics, and SAE standardized it as J514 — the 37° flare system the trade calls JIC.
That lineage explains the boundary. Dash sizing belongs to the flare-tube world, not to pipe threads, which follow their own charts and conventions. When a drawing mixes the two — a port called -4 NPT — read it with suspicion and check the thread itself; the 5-minute bench identification settles which thread you are holding. Mixing the systems is a documented way to order the wrong part.
What does the dash decode to?
Arithmetic, no lookup: dash ÷ 16 = nominal size in inches. -12 is three-quarters, -16 is one inch, and the series runs past -32 for large-bore hose.
Our printable dash size chart maps the full -4 to -32 range to fractional inch and millimetres. Keep it at the desk; the rule is for the field, when the chart is not.
| Dash | Fractional inch | mm | Typical use |
|---|---|---|---|
| -4 | 1/4 | 6.35 | Small instrument and pilot lines |
| -6 | 3/8 | 9.53 | Workhorse instrument tube size |
| -8 | 1/2 | 12.70 | Instrument and hydraulic mains |
| -10 | 5/8 | 15.88 | Medium hydraulic lines |
| -12 | 3/4 | 19.05 | Process and hydraulic distribution |
| -14 | 7/8 | 22.23 | Less common; larger instrument runs |
| -16 | 1 | 25.40 | Hydraulic supply and return lines |
| -20 | 1-1/4 | 31.75 | Larger hydraulic and process runs |
| -24 | 1-1/2 | 38.10 | Manifold and station feeds |
| -28 | 1-3/4 | 44.45 | Rare; special machinery runs |
| -32 | 2 | 50.80 | Large-bore hose and tube headers |
Full printable version: dash size chart
Is -6 the same as 10 mm?
No. The dash is a sixteenths code and the metric column is a metric tube size; catalogs pair them by convention, not by equivalence. -6 sits beside 10 mm, -8 beside 12 mm, -4 beside 6 mm.
The gap is small and fatal: 3/8 inch is 9.53 mm, not 10; 1/2 inch is 12.7 mm, not 12. The sleeve or ferrule has to grip the actual tube, so a -6 fitting on 10 mm tube is a leak waiting for its shift.
The metric-versus-fractional division of the tube world is worked through in metric vs fractional tube sizes. One more wrinkle for international drawings: metric-based dash callouts drop the millimetre number itself, so a -30 thread is a 30 mm reference, not 30/16 inch.
How do you check a dash callout at the bench?
Five steps and one caliper. Do this before the RFQ leaves your desk, not after the parts arrive.
- Read the callout exactly as drawn: -4, -6, -8, -12. Not the catalog description of the part someone quoted you.
- Decide what the line is — tube, hose, or pipe. On hose the dash is bore ID; on tube it is outside diameter.
- Measure the tube OD. 9.53 mm is -6, 12.70 mm is -8; a 10 mm tube is neither and must not take either fitting.
- Check the port thread whenever the callout mixes systems, as in
-4 NPT. A thread check costs minutes; a wrong order costs a return. - Confirm the sleeve or ferrule matches that measured OD. Record wall or schedule separately — the dash says diameter, not wall.
What goes wrong, and what to change
| Symptom | Most likely cause | What to change |
|---|---|---|
| Fitting will not seal on a 10 mm tube | A -6 fitting taken from the metric column; the tube is 10.0 mm, the dash 9.53 mm | Order to the measured tube OD, not the neighbouring column |
| Nut tightens but the joint still moves or weeps | Ferrule sized from the dash label rather than the tube it has to grip | Match the sleeve to the measured OD |
A -8 union will not meet a 1/2 NPT half-coupling |
Dash is tube OD at 12.7 mm; NPS 1/2 pipe is fixed at 0.840 in (21.3 mm) OD | Identify the system before ordering; no adapter bridges it |
| Hose assembly arrives with the wrong bore | Dash read as outside diameter; on hose ends it usually means inside diameter | Read whether the line is hose or tube |
-4 NPT on the drawing, nothing fits |
Two numbering systems written into one callout | Bench thread check first, quotation second |
| Part arrives for a 30 mm metric tube | A metric-based dash callout divided by sixteen | Check whether the callout is metric-based before dividing |
Every row ends in the same place: the number on the drawing describes a diameter in one specific system. The measurement decides, and the measurement is taken on the part in front of you.
What goes on the RFQ?
- dash size as drawn — copy the callout exactly: -6, -8.
- actual tube OD — in inches or millimetres, whichever the shop measures.
- system — JIC 37° flare, SAE, or metric tube; the fitting body must match.
- hose or tube — the dash convention flips between the two.
- thread check — where an NPS or NPT callout sits beside a dash.
- wall or schedule — dash says diameter, not wall.
Those six lines answer the questions a quotation desk would otherwise ask by email.
FAQ
Is -8 the same as 1/2 inch?
As a tube size, yes: 8/16 = 1/2 inch tube OD. As a pipe size, no: 1/2 NPS pipe has a fixed 0.840 in (21.3 mm) OD. Different codes, different diameters.
Does -6 mean 6 mm?
No. -6 is 6/16 inch = 3/8 inch = 9.53 mm. The catalog pairing with 10 mm tube is convention, not equivalence — a 0.47 mm difference the gripping hardware cannot forgive.
What does the dash mean on a hose fitting?
On hose ends the dash commonly denotes hose inside diameter: -6 hose has a 3/8 inch bore. Tube fittings use the opposite convention, dash equals tube OD. SAE 100R5 hose is the documented exception, where dash equals a tube OD.
Is dash sizing the same as NPT?
No. Dash descends from the AN/SAE J514 37° flare tube system; NPT is the ASME tapered pipe-thread system, with size names that match no measured diameter. A drawing mixing them needs a thread check before a quote.
Where does the dash system come from?
American military aviation: Air Force-Navy standards sized lines in sixteenths, the Joint Industries Council carried that into industry, and SAE standardized it as J514 — the 37° flare system known as JIC. Aviation plumbed with tube, not pipe.