Skip to content

Need stainless steel fittings, valves or hose?

Proof Pressure vs Burst Pressure vs Working Pressure

Working, proof and burst pressure on a datasheet: what each number is for, the 1.5x test convention, CWP vs WOG terminology, and what to state on the RFQ.

Sep 28, 2026 · 5 min read · FerruleX Factory

Hex-body compression ball valve with pressure class marking on the body

Proof pressure, burst pressure and working pressure are three different numbers on a valve or fitting datasheet, and mixing them up is how lines get over-rated and valves get mis-specified.

Working pressure is what the component may see in service. Proof pressure is a temporary test pressure used to demonstrate integrity. Burst pressure is where a destructive test actually fails the part.

Design to the working number. Use proof figures to judge the maker’s test method, and burst figures to understand the margin — never as headroom.

Key takeaways

  • Working pressure is the maximum service pressure at stated conditions — the only number you design to; proof and burst are not operating headroom.
  • Proof pressure is a temporary, non-destructive verification test: many valve standards call for a shell test at 1.5× the rated pressure, but the multiple is standard-specific, not universal.
  • Burst pressure comes from destructive testing on samples; it defines the failure boundary and a safety margin, never a target.
  • CWP (cold working pressure) and WOG (water-oil-gas) are both ambient-temperature body ratings in psi — CWP is the clearer modern marking, and the full rating-system picture lives in ball valve ratings explained.

Which number do I design to?

The working number, and only the working number. Everything else on the sheet describes how the maker proves the part, not what you may run it at.

Number What it is What it is for Can you operate there? What it decides for your order
Working (rated, CWP) Maximum pressure permitted in service under stated conditions — temperature, material, fluid The design number; sizing and selection Yes — this is the operating limit The line rating itself; every other number is a check on the maker
Proof (test) Temporary pressure applied to demonstrate integrity — shell and seat tests Factory verification; finds leaks and weak joints without destroying the part No — passing a proof test does not rate the part at the test pressure Whether you accept the test method behind the rating
Burst Pressure at which the component fails in a destructive test Qualification and safety-margin data Never — it is the failure boundary The margin sitting behind the rating; nothing in sizing

The shell test pressurises the body and joints to demonstrate leak-tightness. The seat test checks shutoff. A destructive burst test on samples establishes where failure actually occurs.

Required margins vary by product standard. Hydraulic hose standards, for example, set their own proof and burst multiples. Read the governing standard for the product rather than assuming one universal ratio.

Is proof pressure always 1.5× working pressure?

No. 1.5× is a common shell-test convention in valve standards, not a definition of proof pressure.

The convention itself is proof testing at 1.5× the rated pressure. API 6D, for instance, sets a minimum shell-test pressure at 1.5× the applicable rating, and makers describe shell tests at 1.5× CWP.

State it as what it is: a common convention of several standards. Other product families carry their own multiples, which is why the multiple has to be read from the governing standard.

The practical reading for a buyer: when a datasheet says “shell tested”, the test pressure and its basis are worth asking for. A valve that passed a 1.5× shell test is rated for its working pressure — not for 1.5× working.

CWP or WOG — which marking applies?

Both are body ratings in psi at ambient temperature, and both appear constantly on instrument and commodity valves. They are not the same statement.

Marking What it states Scope What decides which you accept
CWP — cold working pressure Maximum non-shock working pressure across a stated cold-temperature range, commonly −20 °F to 100 °F The rating carries a stated temperature range The clearer, preferred marking — confirm the range covers the duty
WOG — water, oil, gas The older ambient-temperature marking; the letters name a service family Not approval for every oil or combustible gas duty The fluid — check temperature-pressure limits and approvals for it

CWP is the clearer, preferred marking because the rating comes with its temperature range attached. WOG names a service family rather than granting approval for every oil or combustible gas duty.

So they are not automatically interchangeable: check the temperature-pressure limits and any service approvals for the actual fluid. The deeper dive into rating systems — WOG classes, PSI classes, and temperature derating — is its own guide: ball valve ratings explained.

How do I check a datasheet before ordering?

  1. Step 1. Find the working pressure and the conditions attached to it — temperature, material, fluid. A number without its condition is not usable.
  2. Step 2. Look for a test figure and establish its basis. “Shell tested at 1.5× CWP” is a convention; the governing standard is the authority.
  3. Step 3. Keep proof out of the operating column. Nothing on the sheet rates the valve above its working pressure, whatever the shell test pressure was.
  4. Step 4. Read the marking — CWP, WOG or a class designation — then check temperature-pressure limits against your fluid.
  5. Step 5. Ask for the documentation you need before the quote: shell test, seat test, hydrostatic records.

What goes wrong when the numbers get mixed up?

Symptom Most likely cause What to change
Line sized on the shell-test figure Proof pressure read as a rating Size to working pressure; treat the test figure as verification
Valve fitted to a combustible gas because it is marked WOG WOG read as a service approval Check temperature-pressure limits and approvals for the actual fluid
Quote comes back in a class designation you did not specify Rating terminology left off the RFQ State CWP, WOG or the class in the language your spec uses
No hydrostatic records at goods-in Test documentation assumed rather than ordered Name shell test, seat test or hydrostatic documentation on the RFQ
Line passes the hydrotest, then derated at temperature Rating taken at ambient only State working pressure and temperature together, per line

What goes on the RFQ?

Three lines keep pressure specs clean, plus the fluid and the size list they apply to.

  • Working pressure and temperature, per line — the number the valve must hold in service, not the test figure.
  • Test or certification requirement — shell test, seat test, hydrostatic documentation — named explicitly, since these are ordered extras, not assumptions.
  • Rating terminology your spec uses — CWP, WOG or a class designation — so the quote comes back in your language.
  • The actual fluid, so service approvals and temperature-pressure limits get checked against the duty.
  • The size list, carried with the working figures, so class and test needs are quoted together.

Where the duty involves isolating a pressurised line for maintenance, the double-block thinking in double block and bleed valves explained covers the isolation side.

FerruleX quotes the class with the valve and confirms any test documentation on the RFQ — state working pressure, temperature and test needs with the size list. Request a factory quote.

FAQ

What is the difference between working pressure and burst pressure? Working pressure is the maximum the component may see in service; burst pressure is where a destructive test fails it. The gap between them is a safety margin for spikes, fatigue and variation — design to working, never toward burst.

Is proof pressure always 1.5× working pressure? No — 1.5× is a common shell-test convention in several valve standards, but the multiple is standard- and product-specific. Other families set their own proof and burst figures. Treat 1.5× as a convention to confirm, not a rule.

Does passing a proof test mean the valve is rated higher? No. A shell test at 1.5× rated pressure demonstrates integrity; the valve remains rated at its working pressure. Proof pressure is a verification, not an operating ceiling.

What does CWP mean on a valve? Cold working pressure — the maximum non-shock working pressure across a stated cold-temperature range, typically −20 °F to 100 °F. It is the clearer modern marking for an ambient body rating.

Is WOG the same as CWP? They are both ambient-temperature psi body ratings, and often numerically equal, but not automatically interchangeable: WOG is the older water-oil-gas marking and names a service family without granting universal service approval. Check temperature limits and approvals for the actual fluid.

Related articles

More guides for stainless steel fittings buyers.