A corrugated metal hose assembly is a made-to-order component: the core, braid, length and end fittings are chosen for your service, not picked off a shelf. A complete spec gets an accurate quote the first time; a vague one gets questions back.

The quick answer: put seven lines on the RFQ — media, temperature, maximum working pressure with its surge pattern, bore and live length, end connections on each end, movement and cycle duty, and cleanliness or certificate requirements. Those seven get an accurate quote first time. Leave movement blank and the hose is sized on assumption, not duty.

Key takeaways

  • A hose RFQ needs seven facts to be quotable: media, temperature, working pressure (including surges), size and length, end connections, movement or vibration duty, and cleanliness requirements.
  • Pressure claims are cold claims: temperature derates the hose, and pulsating or shock service demands a lower working pressure than the catalog table suggests.
  • Corrugations cost pressure drop — a corrugated hose flows noticeably worse than smooth pipe of the same bore — so size for velocity and ΔP, not just the end fittings that fit.

Which hose assembly do you actually need?

Nothing here is picked from a catalogue. Each line closes off an option, and any line you leave out is filled by the factory’s assumption rather than your service. The table is the decision; the steps after it are the order to write it in.

Spec item What to state What it decides
Media Fluid or gas, plainly named Core and braid alloy
Temperature Service temperature, internal and external Derates the pressure rating; sets seal limits
Working pressure Maximum steady, plus surge behaviour Whether a lower working rating is needed
Size and length Nominal bore; overall vs live length How much movement the assembly can absorb
End connections Standard on each end How the welded transitions are built
Movement and cycle duty Axial/lateral/angular movement, how often Pitch, bend radius and live length
Cleanliness and documentation Degreasing, certificates, photos What is scheduled at quote, not after dispatch

Writing the seven lines, in order

  1. Step 1 — name the media and the alloy it forces. SS304 for air, water and oil; SS316 or 316L where chlorides or marine exposure are present; a special alloy for aggressive chemicals.
  2. Step 2 — state service temperature, internal and external. Every pressure rating is a cold rating, so temperature sets the derated figure you can actually use.
  3. Step 3 — quote maximum working pressure, then the duty. Steady, pulsating or shock. Pulsating service takes a lower working rating; shock takes more margin again.
  4. Step 4 — give the nominal bore and the live length. The corrugated section between the fittings, not the tip-to-tip dimension.
  5. Step 5 — name the end connection on each end, then the movement. Movement and cycle duty decide pitch, bend radius and live length; cleanliness and documents come last.

What media and temperature does it see?

Media picks the alloy. SS304 core and braid cover general air, water and oil service; SS316 or 316L where chlorides or marine exposure are present; special alloys for aggressive chemicals. State the media plainly — “process fluid” is not a spec. The alloy comparison is in SS304 vs SS316.

Temperature comes next. Every hose working-pressure rating is a cold rating that derates as temperature rises, so quote the derated figure for your service temperature. The braid and the seals must survive that temperature too, internal and external. A hose that meets its rating cold can sit outside it hot.

What pressure must it hold?

Quote the maximum working pressure, then the duty pattern. Constant pressure is kind. Pulsating pressure — reciprocating compressors, metering pumps, fast valves — fatigues corrugations and braid and demands a lower working rating than the catalogue figure. True shock conditions demand more margin again.

State surges honestly on the RFQ. Ask for the proof or hydrostatic test with the supply: an assembly should arrive tested well above its working pressure, with the certificate available on request. If the line carries gas, say so — gas service raises the integrity bar.

How long is it — and which length?

State the nominal bore and the length, but know which length you are quoting. Overall length is end to end. Live length is the corrugated section between the end fittings, and it is the live length that absorbs movement.

A hose that looks long enough overall may have too little live length to flex without stress. Too much live length on a vertical run droops and fatigues under its own weight at temperature. Replacing an existing assembly? Measure the live section, not the tip-to-tip dimension.

Corrugations cost pressure drop. Loss through corrugated hose is substantially higher than through smooth pipe of the same bore — for some corrugation profiles close to double. On pumped or high-flow runs, size for acceptable velocity and ΔP, not merely to match the end connections.

Which ends, braid and finish?

Flanges, fixed or swivel; NPT or G threads; tri-clamp sanitary ends; weld ends. The choice belongs to the equipment being joined, not to the hose. Tri-clamp ends follow the clamp sizing of the line, so read what are tri-clamp fittings before ordering clamp-end hose.

Specify the standard on each end when they differ, so the welded transitions are built right the first time. Braid layers set the pressure class: one for moderate duty, two where the rating demands it, plus armour or sleeves where abrasion threatens the braid.

Cleanliness and documentation are scheduled at quote, not scrambled for after dispatch:

  • Degreasing, where the line runs oxygen service
  • Cleaned and capped ends, for food or pharma
  • Standard shop finish, for utility service
  • Proof or hydrostatic test certificate, available on request
  • Certificates and photos of the finished assembly, agreed up front

What movement must it absorb, and how often?

This line is the one most often left blank, and the one that most often kills the hose. State what the assembly must absorb: axial growth, lateral offset, angular misalignment, vibration. Then state how often.

Duty What the hose needs What decides it
Static installation Standard live length, no flexing duty Nothing to absorb
Occasional thermal cycling Live length sized for the axial growth How much the run grows
Continuous dynamic flexing Generous live length, close-pitch core, bend radius well above the minimum Cycles and travel per cycle

Static installation, occasional thermal cycling and continuous dynamic flexing are three different products. Dynamic duty needs generous live length, a close-pitch core and a bend radius well above the minimum.

Large movements are beyond what a single hose should take. Beyond roughly a hundred millimetres of axial travel, a purpose-built expansion joint is the honest answer, not a longer hose. Permanently misaligned runs deserve re-routing.

When a hose fails, read the symptom before you re-order:

Symptom Most likely cause What to change
Hose droops and fatigues on a vertical run Too much live length for the run Cut back the live length
Corrugation cracks at the fitting Too little live length for the movement asked of it More live length, close-pitch core
Braid and corrugation fatigue under pulsation Steady working rating applied to pulsating service State the surge pattern; take a lower working rating
Braid worn through Abrasion against structure or adjacent pipe Armour or a protective sleeve
Flow choked, pump short of head Bore matched to the fittings, not to velocity Size the bore for velocity and ΔP
Leak at the welded transition End standard not stated, or stated for one end only Specify the standard on each end

FerruleX builds corrugated hose assemblies to order — start from the corrugated hose category, the flanged corrugated hose style for pipe connections, or the threaded hose style for utility jumps, and send the seven-line spec for a factory quote.

FAQ

What do I need to quote a metal hose assembly? Seven lines: media, temperature, maximum working pressure with surge behaviour, nominal bore and length, end connections on each end, movement and cycle duty, and cleanliness or certificate requirements.

Does hose length mean overall or live length? Overall is end to end; live length is the corrugated section between fittings. Movement is absorbed by the live length, so specify or measure that section. Adequate overall length can still leave a hose too stiff to flex.

How much pressure drop does corrugated hose add? Substantially more than smooth pipe of the same bore — for some corrugation profiles close to double. On high-flow runs, check velocity and pressure drop before sizing.

What end connections can a hose assembly have? Flanged, fixed or swivel; NPT or G threaded; tri-clamp sanitary; weld ends; and mixed combinations. Name the standard on each end so the welded transitions are built correctly.

When is a hose the wrong solution entirely? Beyond roughly a hundred millimetres of axial travel, use a purpose-built expansion joint. Permanently misaligned pipe runs deserve re-routing. A hose is a flexible jumper, not a substitute for pipe stress design.

Related articles