The answer is that you do not choose between them. Nearly every flexible metal hose is a corrugated stainless steel core with a woven wire braid over it. What you actually decide is the corrugation profile, the pitch and how many braid layers.
Key takeaways
- Flexible metal hose is a system, not a single wall: a corrugated stainless core flexes, and a wire braid cover restrains the core from elongating under pressure — unbraided corrugated tube would extend like a spring and fail quickly in pressure service.
- Annular corrugations (complete rings) flex and drain better; helical corrugations (one continuous spiral) suit higher pressure and smoother flow; close pitch (more corrugations per length) bends tighter and lasts longer in flexing duty than open pitch.
- The flexibility-versus-pressure trade-off is decided by corrugation profile and braid: more flexibility means lower pressure capacity, and a second braid layer buys pressure back — while bending below the minimum bend radius kinks corrugations permanently.
Which one do I need?
“Corrugated or braided?” is the wrong question once you see how corrugated stainless steel hose is built: virtually every flexible metal hose is both.
The corrugated core is a thin-wall stainless tube formed into a series of corrugations, each one a tiny accordion fold. Bending and movement open and close the folds instead of stressing the wall. That is why the hose survives thermal growth, vibration and misalignment that would crack rigid pipe.
The braid is a sheath of woven stainless wire over the core. It does almost nothing to the hose’s flexibility — its job is restraint. Internal pressure pushes axially on the corrugations, and without the braid the hose would elongate uncontrollably under that thrust.
The braid carries that thrust, raises the working pressure, damps vibration and shields the core from abrasion. So “braided hose” in a catalogue almost always means braid-reinforced corrugated hose: the two features are partners, not alternatives.
In practice the question narrows to four decisions.
| Decision | Options | Decisive factor |
|---|---|---|
| Core profile | Annular, helical | Drain-down on the run versus pressure for a given wall |
| Pitch | Close, open | Movement in service and the space the bend needs |
| Braid | One layer, two layers | The working-pressure class the line must hold |
| Cover | Bare braid, armor or sleeve | Abrasion and washdown at the installation |
Annular or helical, close or open pitch?
Two geometry choices define the core’s character.
| Profile | Geometry | Character | Decisive factor |
|---|---|---|---|
| Annular | Complete rings at right angles | Flexes freely, drains well | Steam, condensate, general duty |
| Helical | One continuous spiral | Higher pressure for wall thickness, smoother flow, traps condensate on horizontal runs | Gas, higher-pressure transfer |
| Close pitch | More corrugations per length | Tighter minimum bend radius, longer flex life | Vibration and frequent movement |
| Open pitch | Fewer corrugations per length | Stiffer profile | Exhaust, static or slow-moving runs |
Annular close-pitch is the default for instrument and steam jumpers that must flex repeatedly; open-pitch helical appears where flexibility hardly matters.
Do I need one braid layer or two?
Every design change that adds flexibility removes pressure capacity, and vice versa. Deeper, closer corrugations bend easily but present a weaker wall to pressure. Shallower profiles hold pressure but fight bending.
The braid is the balancing tool. One layer suits moderate working pressures, and a second braid layer raises the rating further at a modest cost in stiffness and price.
This is why catalogue tables pair each hose type with its own working-pressure column. There is no single “stainless hose” rating, and quoting a hose without its braid specification is quoting half a product.
Which hose for which service?
| Service | Core and pitch | Braid | Decisive factor |
|---|---|---|---|
| Steam and condensate jumpers | Annular core, close pitch | Single braid — drains between cycles, flexes with thermal growth | Drain-down between cycles |
| Gas and higher-pressure transfer | Helical or heavier wall | Double braid where the pressure class demands it | The pressure class |
| Vibration isolation at pumps and compressors | Close-pitch annular | Braid sized for the pressure; the braid damps as well as restrains | Pump or compressor vibration |
| Abrasive or washdown environments | As the duty requires | Add an interlock armor or protective sleeve over the braid | Abrasion and washdown |
FerruleX builds corrugated stainless hose assemblies to order — browse the corrugated hose category or the male-female threaded hose and tri-clamp corrugated hose styles. Send media, pressure, movement and end connections for a factory quote.
Why does a hose fail at one corrugation?
The failure that ends most hose lives early is simple abuse: bending tighter than the rated minimum bend radius. Past that radius the corrugations take a permanent set.
| Symptom | Most likely cause | What to change |
|---|---|---|
| One corrugation flattens, then cracks circumferentially | Bending past the minimum bend radius; in dynamic service the roots work-harden | Re-route to respect the static radius and the larger dynamic radius |
| Hose keeps a permanent curve after installation | Permanent set taken past the minimum bend radius | Add live length, or use an elbow where the routing turns sharply |
| Hose elongates or pulls on the fittings under pressure | Braid missing, damaged or not sized for the class | Specify the braid layer count against the working-pressure class |
| Braid frets, core abraded | Rubbing on structure, unsupported run, no sleeve | Support vertical runs, avoid twisting, add interlock armor or a sleeve |
| Tight arc forced close to a fitting | Live length too short between end fittings | Extend the live length so movement is absorbed without tight arcs |
Respect three numbers and most of this disappears. The first is the minimum static bend radius for installation. The second is a larger dynamic radius for anything that flexes in service, often double or more of the static figure.
The third is the hose’s live length, the corrugated section between end fittings. It must be long enough to absorb movement without forcing tight arcs.
Support vertical runs, avoid twisting during installation, and use elbows where the routing needs a sharp change of direction rather than forcing the hose into it.
How do I install it without kinking it?
- Measure the routing first, including the bend the pipework cannot avoid.
- Check the tightest point of that route against the minimum static bend radius.
- Check the dynamic radius, often double or more of the static figure, if the line flexes in service.
- Set the live length, the corrugated section between end fittings, long enough to absorb movement without tight arcs.
- Support vertical runs, avoid twisting the hose during installation, and use an elbow for a sharp change of direction.
Before you send an enquiry, the specification should already fix these:
- The media and its temperature.
- The working pressure and the braid layer count that holds it.
- Whether the movement is static or dynamic, and how much of it there is.
- The bend radius available at the tightest point of the route.
- The end connections and the live length needed between them.
- The environment: abrasion, washdown, condensation on horizontal runs.
FAQ
Is braided hose different from corrugated hose? No. Almost all flexible metal hose is a corrugated core under a braid cover. The braid restrains the core and raises the working rating; the corrugations supply flexibility. Unbraided corrugated tube is for low-pressure or shielding uses, not pressure hose.
What is the difference between annular and helical corrugation? Annular corrugations are complete rings at right angles to the axis; helical is one continuous spiral. Annular flexes and drains better, the usual pick for steam. Helical holds more pressure for a given wall but traps condensate on horizontal runs.
What does hose pitch mean? The spacing of the corrugations. Close pitch packs more corrugations into the length, giving a tighter minimum bend radius and longer life in repeated flexing. Open pitch is stiffer where flexibility hardly matters.
Why does my metal hose fail at one corrugation? Bend-radius or flexing abuse. Corrugations bent past the minimum radius take a permanent set; in dynamic service the roots work-harden and one flattens and cracks first. Check installed radius, dynamic radius and live length first.
Does adding a second braid layer matter? Yes. Each braid layer raises the working-pressure capacity of the same core, at some cost in stiffness and price. It lifts a flexible hose into a higher pressure class without changing corrugation profile.
Related: how long stainless hoses last.