Skip to content

Need stainless steel fittings, valves or hose?

High-Pressure Female Globe Valve — FerruleX stainless steel fittings

High-Pressure Female Globe Valve — Types & Sizes

High-Pressure Female Globe Valve: HP stainless throttling valve, female thread. SS316 preferred. FerruleX RFQ. Stocked sizes ship fast. Fast stock shipping.

Brand
FerruleX
Material
SS304 / SS316 / SS316L
Ends
Female thread 1/8"–1" / M10–M24
Pattern
Straight or angle
Pressure
4600 psi / 32 MPa

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

The high-pressure female globe valve sits in a different body group from the 2000 psi needle valves: this one is catalogued at 4600 psi / 32 MPa, female threaded, made in 304, 316 or 316L. Two things follow. First, the class is four and a half times the standard needle family, which is what a high-pressure sample or injection line needs. Second, it stays ambient duty — a heavier body does not add temperature headroom, so duty temperature has to be checked separately. Threads run 1/8 to 1 in and M10 to M24 in ZG(R), NPT, G or M form, with compression, weld, thread and reducing ends listed in the group and straight or angle patterns only.

The 4600 psi / 32 MPa group, female threaded, in 304, 316 or 316L. A globe plug against a seat gives a wider flow path than a needle at the same travel, and the class is what separates this body from the 2000 psi needle family. Ambient duty only. Threads 1/8–1 in and M10–M24.

Class
4600 psi / 32 MPa — a different body group from the 2000 psi needles.
Seat
Globe plug and seat, wider flow path than a needle at the same travel.
Threads
1/8"–1" and M10–M24, in ZG(R), NPT, G or M form.
Temperature
Ambient duty only; the pressure class adds no heat headroom.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS304 / SS316 / SS316L
EndsFemale thread 1/8"–1", M10–M24
PatternsStraight or angle
Pressure4600 psi / 32 MPa
TemperatureAmbient service only

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

Is this globe valve for metering or for shut-off?

It throttles. The plug and seat give a wider flow path than a needle at the same travel, which suits trimming flow on a sample or injection line rather than fine metering resolution. It is not a soft-seated isolation valve.

Which patterns are available, straight or angle?

Straight and angle only. An angle body turns the flow through the seat in one corner, which removes a bend from the line, while the straight pattern drops into a run without offsetting the pipe.

How does the flow capacity here compare with a needle valve?

It is higher, and coarser. The globe plug opens a wider flow path than a needle at the same travel, so a given stem turn moves more flow, which gives less fine resolution near the seat and a shorter useful throttling band.

How is the stem packed and adjusted?

The stem runs through a packed gland. Take up the packing nut only until weepage stops, because over-tightening adds friction, makes the plug jump off the seat and wears the packing out early.

Should it be opened slowly on a high differential?

Yes. Crack it open a fraction and let the pressure equalise across the plug before opening further, since a full differential at 4600 psi / 32 MPa driven straight through the seat is what damages trim.

What damages the plug tip or seat first?

Wire drawing. Throttling a small opening at full differential turns the jet abrasive and cuts a groove across the plug tip and seat, so keep the valve either well open or fully closed where the line allows.