Skip to content

Need stainless steel fittings, valves or hose?

2-Valve Manifold — FerruleX stainless steel fittings

2-Valve Manifold

2-Valve Manifold: isolate and vent for static pressure gauges and transmitters. SS304/316 stainless. FerruleX factory RFQ — confirm ports and pressure class.

Brand
FerruleX
Material
SS304 / SS316 / SS316L
Ports
1/8"–1" / M10–M24
Configuration
One block, one vent
Pressure
4600 psi / 32 MPa

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

A 2-valve manifold does two things to a gauge or an absolute-pressure transmitter: it isolates the instrument from the process, and it vents the instrument side so the trapped pressure is gone before the device comes off the line. One block valve, one vent, one body — and the order matters, because the vent sits on the instrument side of the block: isolate first, vent second, never the reverse. It is not the body for a differential transmitter; two process legs need a block on each and an equalizer between them, which is the three-valve arrangement. This group runs 4600 psi (32 MPa) at ambient temperature, with 1/8"–1" and M10–M24 ports in ferrule, weld, thread or reducing ends, in 304, 316 or 316L stainless.

Block and vent for a gauge or absolute-pressure transmitter: isolate the instrument, then release the trapped pressure on the instrument side. One body, two valves, 4600 psi (32 MPa) at ambient, ports 1/8–1 in and M10–M24. Not the body for a differential transmitter, which needs a block on each leg and an equalizer between them.

Duty
Gauge or absolute-pressure instruments; isolate plus vent.
Order
Isolate first, then vent — the vent sits on the instrument side.
Limits
4600 psi (32 MPa) at ambient temperature.
Ports
1/8"–1" and M10–M24, ferrule or threaded ends.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS304 / SS316 / SS316L
Ports1/8"–1", M10–M24
Configuration2 valves: block + vent
InstrumentGauge or absolute-pressure transmitter
Pressure4600 psi / 32 MPa
TemperatureAmbient service

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

What are the two valves actually doing?

One valve blocks the process from the instrument; the other vents the instrument side so the trapped pressure is released before the device comes off the line or is calibrated.

Does the vent have a shut-off of its own, or is it always open?

Yes. The vent is a valve in its own right, so it stays closed in normal service and is opened only after the block valve has been shut.

Can I put this on a differential-pressure transmitter?

No. Two process legs need a block on each and an equalizer between them, which is the three-valve arrangement. This body serves a gauge or an absolute-pressure transmitter only.

Do I have to state the thread form when ordering?

State the thread form on the order. Taper threads of different families do not seal against each other, so a male and female of mixed origin will leak even when the size matches.

Is this valve for throttling flow or for isolation only?

Isolation only. These valves are made to be fully open or fully shut; using one to throttle flow wears the seat and gives poor control at low openings.

Does the body need a fixed orientation when it goes in?

Position the body for gauge readability before the connections are finally pulled up, then leave it. Once ferrules or threads are made up, the body is fixed and should not be turned to reposition it.