Skip to content

Need stainless steel fittings, valves or hose?

3-Valve Manifold — FerruleX stainless steel fittings

3-Valve Manifold

3-Valve Manifold: block and equalize for differential pressure transmitters. SS304/316 stainless. FerruleX factory RFQ — confirm ports and pressure class.

Brand
FerruleX
Material
SS304 / SS316 / SS316L
Ports
1/8"–1" / M10–M24
Configuration
Two blocks, one equalizer
Pressure
4600 psi / 32 MPa

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

A 3-valve manifold is the standard mount for a differential-pressure transmitter: two block valves, one per impulse leg, and a central equalizer tying the high and low sides together. Running condition is blocks open, equalizer closed. The equalizer is opened for zeroing, and for bringing both sides to the same pressure before either block is moved, so the cell never takes a one-sided load. The trap with this body is the count: the third valve is the equalizer, not a bleed, so a procedure that calls for venting each leg independently is not served by it — that is the five-valve arrangement. This group runs 4600 psi (32 MPa) at ambient, ports 1/8"–1" and M10–M24, in 304, 316 or 316L, with ferrule, weld, thread or reducing ends.

Two blocks and an equalizer for a differential-pressure transmitter: isolate each impulse leg, and tie the two sides together for zeroing without a one-sided load on the cell. 4600 psi (32 MPa) at ambient, ports 1/8–1 in and M10–M24. The third valve is not a bleed — order five valves when each leg has to be vented on its own.

Equalizer
Ties high and low sides for zeroing before the blocks move.
Not a bleed
The third valve equalizes; it does not vent either leg.
Limits
4600 psi (32 MPa) at ambient temperature.
Step up
Independent leg venting means the five-valve body.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS304 / SS316 / SS316L
Ports1/8"–1", M10–M24
Configuration3 valves: 2 blocks + equalizer
InstrumentDifferential-pressure transmitter
Pressure4600 psi / 32 MPa
TemperatureAmbient service

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

What does the third valve do?

It is the equalizer. Opening it ties the high and low sides to the same pressure, which is what zeroing a differential transmitter requires and what keeps the cell from taking a one-sided load while a block is moved.

In what order do I operate the valves?

Running condition is both blocks open and the equalizer closed. To zero, open the equalizer first, then close the blocks; zero the transmitter, open the blocks, and close the equalizer last.

Can I vent a leg before pulling the transmitter?

Not from this body. The blocks isolate the process, but the trapped leg has no vent of its own, so it drains at a broken joint. Independent venting is the five-valve arrangement.

Which pressure class does it cover?

The body is rated 4600 psi (32 MPa) at ambient temperature, which is the high-pressure class. The wall section and the valve trim are sized for that rating rather than for utility service.

What thread forms can the ports have?

Thread ends are cut to the form you order, and the port list is 1/8" to 1" and M10 to M24. NPT and BSPT will not mate, so specify one form per body and do not pair the two at a joint.

Can I use it on a single gauge instead of a transmitter?

It is built for a differential-pressure transmitter, where two impulse legs need isolating. A gauge reads one side, so the second block and the equalizer both sit unused and add joints that can weep.

Related products