Skip to content

Need stainless steel fittings, valves or hose?

Compression Bulkhead Union — FerruleX stainless steel fittings

Stainless Steel Compression Bulkhead Union — Sizes

Compression Bulkhead Union: panel-pass stainless steel compression fittings, double ferrule. SS316/304. FerruleX RFQ. Stocked sizes ship fast. OEM RFQ welcome.

Brand
FerruleX
Material
SS316 / SS316L / SS304
Tube OD
3–25 mm / 1/8"–1"
Type
Compression bulkhead union
Pressure
1000 psi standard / 4500 psi high-pressure

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

The panel hole sets the geometry of this joint. A bulkhead union body is drawn through the bore and held from both faces, so the wall becomes the mechanical anchor for an otherwise continuous tube run. Each end carries a ferrule connection: tube inserted, nut drawn down, ferrule swaged onto the OD, and the joint remade only by cutting the tube. Sizes run OD 3–25 mm, the same range as 1/8 in to 1 in, with M5 to M24 threads in ZG(R), NPT, G or M form. Bodies come in SS316, SS316L, SS304 or copper. Working pressure is about 1000 psi standard and about 4500 psi in the high-pressure version.

The bore is the reference, so drill to the diameter on the drawing and deburr both lips before the body goes in. Draw the panel nut up first, then make the tube connections; a ferrule remade after the panel nut has moved rarely seats the same way twice. Keep the panel nut reachable for service.

Panel fit
Body passes the bore and is clamped from both faces of the wall.
Sizes
OD 3–25 mm and 1/8 in to 1 in, with M5 to M24 threads.
Threads
ZG(R), NPT, G and M forms match the mating port.
Pressure
About 1000 psi standard, about 4500 psi in the high-pressure version.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS316 / SS316L / SS304
Tube OD3–25 mm / 1/8"–1"
TypeCompression bulkhead union
Pressure1000 psi standard / 4500 psi high-pressure

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

Should the panel nut be drawn up before the tube connections are made?

Yes. Set the body in the bore and tighten the panel nut against the wall first, then make both tube connections; a ferrule that is remade after the panel nut has moved rarely seats the same way twice.

How deep should the tube enter the fitting?

Push the tube in until it stops against the shoulder, then draw the nut down. Seating short of the shoulder leaves the ferrule gripping too little tube and the joint will not hold pressure.

How should the tube end be prepared before assembly?

Cut the tube square and deburr both the outside and the bore, then blow the swarf out. A burr or an out of square cut lets the ferrule seat off centre and the joint leaks.

Can the joint be remade, and are new ferrules needed?

Cut the tube back behind the old swage and fit new ferrules; the used ferrule is not reused. Remaking on the same ferrule is what produces the leaks that appear after a service strip down.

How do I tell a leak at the tube joint from one at the threaded end?

Dry both faces and pressurise briefly. A leak from behind the nut points to the ferrule and tube, while a leak at the port face points to the thread or the sealing face of the body.

Does vibration affect a bulkhead joint, and should the tube be supported?

Support the tube close to each nut so panel vibration is not carried into the ferrule. An unsupported run works the joint and the leak appears at the swage rather than the panel.