Skip to content

Need stainless steel fittings, valves or hose?

Compression Check Valve — FerruleX stainless steel fittings

Compression Check Valve

Compression Check Valve: stainless steel check valve, double-ferrule ends, 2000 psi / 12 MPa. SS304/316. FerruleX factory RFQ. Stocked sizes ship fast.

Brand
FerruleX
Material
SS304 / SS316 / SS316L
Ends
Compression (double ferrule)
Size
OD 1/8–1 in typical
Pressure
2000 psi / 12 MPa

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

Ferrule-ended check valves hold flow in one direction on stainless tubing from 3 mm to 16 mm OD, closing when downstream pressure turns back toward the source. Bodies are SS304, SS316 or SS316L. Tube ports take 1/8 to 1 inch OD (3.175–25.4 mm); thread ports run M10 to M24 in ZG, NPT or G. Working pressure for the line is 2000 psi, about 12 MPa, at ambient temperature. Usual service is petrochemical, food processing, pharmaceutical, shipbuilding and construction, plus energy and environmental plant. Compression ends grip the tube directly, so the valve sits in a straight run of existing line. It is a one-way element, not an isolation point; fit a separate valve upstream where the line has to be shut for service.

Two numbers carry the order: tube OD at each end and the thread standard where the line changes over. ZG, NPT and G are all produced, so name the one the mating port uses instead of letting it be inferred. Material follows the tubing: SS316L where the line is 316L.

Duty
One-way flow only; no isolation function.
Ports
Compression 1/8–1 in tube OD, or ZG, NPT and G threads.
Alloy
SS304, SS316 and SS316L bodies.
Rating
2000 psi (12 MPa) at ambient temperature.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS304 / SS316 / SS316L
EndsCompression (double ferrule)
SizeOD 1/8–1 in typical
Pressure2000 psi / 12 MPa

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

What pressure does the valve open at, and can it be set?

Opening is flow driven, so there is no setting to adjust on site. Any figure for it belongs to one body size and one medium, and is confirmed on the drawing for the size ordered rather than read off the line rating.

What pressure drop does the valve add when open?

The closing element sits in the flow path, so some drop is unavoidable and it grows with flow rate. Size the body on the tube bore rather than on the port thread, and the penalty stays small.

Which way does the flow arrow point?

The arrow on the body marks the permitted flow. Fit the valve so the arrow follows the line direction; reversed, it reads as a blocked line rather than a leaking one, which is the commonest commissioning fault.

Does it seal tight against reverse flow?

It closes on differential pressure, so it is not a zero-leak isolator and can weep as that differential falls away. Where a tight reverse seal is required, add a ball or needle valve behind it.

Why do check valves chatter or slam in service?

Chatter starts when flow hovers near the opening point; slamming comes from a quick reverse surge, as when a pump stops. A body sized to the real flow and a straight approach reduce both.

Where does the valve go relative to a pump?

Put it on the discharge side, with as much straight run between pump and valve as the layout allows. Set close to an elbow, the closing element sees swirl and the seat wears unevenly.