Skip to content

Need stainless steel fittings, valves or hose?

Female Thread Check Valve — FerruleX stainless steel fittings

Stainless Steel Female Thread Check Valve — Types

Female Thread Check Valve: stainless steel check valve, NPT/G female ends, 2000 psi / 12 MPa. SS304/316. FerruleX RFQ. Stocked sizes ship fast.

Brand
FerruleX
Material
SS304 / SS316 / SS316L
Ends
Female thread
Threads
NPT / G / ZG(R) / Metric
Pressure
2000 psi / 12 MPa

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

Both ends are female, so nothing has to be made up on a ferrule: the valve drops between two male threads and the hex takes the wrench. Bodies come in 304, 316 or 316L, tapped NPT, G or ZG(R), in 1/8 to 1 inch and M10 to M24. Working pressure is listed at 2000 psi, about 12 MPa, at ambient temperature. The poppet closes against the seat you specify, and spring rate sets the cracking pressure, so both go on the order. An arrow marks flow direction; fit it before the line is pressurised. Keep sealant on the male thread only.

Nothing about a female-ended check valve is adjustable in service, so the specification has to be right at order: thread standard per port, seat type, spring rate and flow direction. Ambient temperature is the ceiling for the standard build. If the element has to be inspected, a union or ball valve upstream keeps the line workable.

Body
304, 316 or 316L, with the poppet and spring held inside one body.
Threads
NPT, G or ZG(R) female on both ports, tapped to order.
Port size
1/8 to 1 inch and M10 to M24.
Pressure
2000 psi, about 12 MPa, at ambient temperature.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS304 / SS316 / SS316L
EndsFemale thread
ThreadsNPT / G / ZG(R) / Metric
Pressure2000 psi / 12 MPa

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

What sets the cracking pressure of this valve?

Spring rate. The spring inside the body is chosen at order, so cracking pressure is fixed by the spring fitted rather than adjusted in service. State the pressure you need and the works matches a spring to it.

Which way round must the body be fitted?

Flow passes one way only and the arrow on the body shows the permitted direction. Fit the valve before the line is pressurised, because a reversed body blocks the line instead of protecting it.

Can the valve be mounted vertically?

The body can sit in any attitude, vertical included, because the poppet is spring loaded rather than gravity returned. What matters is that the arrow points down the intended flow path, not the mounting angle.

Soft seat or metal seat, and does it leak back?

Seat type goes on the order: a soft seat gives the tighter shut off, a metal seat tolerates higher temperature. Neither is a leak proof guarantee, so a line that must hold dead tight needs a separate isolation valve.

How much pressure does the valve drop when open?

Every spring check valve costs some pressure across the seat, and the figure rises with flow rate. Size the body so normal flow sits well below the maximum, otherwise the poppet chatters and the drop grows.

Can the valve be opened up for cleaning?

No. The poppet and spring are held inside one sealed body, so the unit is not meant to be dismantled for cleaning. Flush the line before fitting, and keep a union upstream if the element has to be inspected.