Skip to content

Need stainless steel fittings, valves or hose?

Female Split-Body Check Valve — FerruleX stainless steel fittings

Female Split-Body Check Valve

Female Split-Body Check Valve: serviceable stainless steel check valve, female threads, 2000 psi / 12 MPa. SS304/316. FerruleX factory RFQ. Fast stock shipping.

Brand
FerruleX
Material
SS304 / SS316 / SS316L
Body
Split / serviceable
Ends
Female thread
Pressure
2000 psi / 12 MPa

Request a factory quote

  • Stock5–7 days after confirmation
  • Make to order15–25 days production
  • Payment / termsT/T ~30% or L/C · FOB Shanghai / Ningbo
  • OEMLogo and drawings accepted · price on RFQ

Description

Two threaded halves make up the body: break the joint and the spring and disc lift out while the line stays in place. Bodies are turned from SS304, SS316 or SS316L with female ZG, NPT or G ends from 1/8 to 1 inch and M10 to M24. Working pressure is quoted at about 2000 psi (12 MPa) at normal ambient temperature. Petrochemical, food, pharmaceutical and marine lines use the pattern where backflow protection has to be opened and inspected rather than sealed for life. After cleaning, the joint goes back to the drawing torque; a loose seam weeps before the seat ever does. Order the seat and spring as a spare line if the element is pulled on a fixed interval.

Body halves are matched at the factory; keep them together through cleaning so the seat face stays concentric. Isolate and drain the run before breaking the joint, and renew the joint seal if it has taken a set. Flow direction is stamped on the housing, and a valve fitted the wrong way round has to come out again.

Body
Housing splits at a threaded joint so the disc and spring lift out in place.
Ends
Female ZG, NPT or G threads from 1/8 to 1 inch and M10 to M24.
Alloy
Machined in SS304, SS316 or SS316L to the order.
Pressure
About 2000 psi (12 MPa) at normal ambient temperature.

Specifications

SpecificationValue
BrandFerruleX
MaterialSS304 / SS316 / SS316L
BodySplit / serviceable
EndsFemale thread
Pressure2000 psi / 12 MPa

Request Quote

Prices stay on the RFQ. Send size, material, quantity and destination — the factory replies with price, lead time and packing. Packing, payment and the usual quote questions are on thedelivery pageand the FAQ.

Request a factory quote

Questions about this part

What pressure does it take to open the disc?

Cracking pressure is set by the spring fitted to the valve, so it is confirmed with the order rather than assumed; state the minimum differential the line can give up and the spring is matched to it.

Does the valve have to be mounted in a vertical line?

No. The spring closes the disc in any attitude, so horizontal runs and vertical up-flow both work; mount it with the flow upwards where the line allows, as gravity then helps the disc seat.

How do I know which way the flow should run through it?

Flow direction is stamped on the housing, so fit the valve with the marked arrow pointing downstream. A valve installed the wrong way round passes nothing in the intended direction and has to come out again.

How is the valve cleaned and the disc replaced?

Isolate and drain the run, then break the threaded joint and lift out the disc and spring; the body halves are matched at the factory, so keep them together and renew the joint seal if it has taken a set.

Why does a check valve chatter or slam in service?

Both faults come from sizing: a valve far larger than the duty runs part open and the disc flutters, while a small one on a fast-closing line seats hard. Match the valve to the actual flow.

How tight is the shut-off against reverse flow?

The disc closes on reverse flow only, so treat the valve as backflow protection and not as positive isolation; seat material is agreed at the order, and the joint seam is the first place to look if the body weeps.