Stainless metric tube-to-male-connector compression fitting with ground finish

Bite-type fittings are the European compression standard: DIN 2353 tube fittings that seal on a 24-degree cone and grip the tube with a cutting ring — a hardened sleeve whose edges bite into the tube’s outside diameter as it tightens.

If a drawing says “24° cone”, “cutting-ring fitting” or simply “metric compression”, it is describing this one system. Three parts do the work, and the series call-out — LL, L or S — sets the pressure class. What follows is the selection logic, the make-up rules and the failure modes.

Key takeaways

  • A bite-type fitting (DIN 2353) seals on a 24° cone inside the body and grips the tube with a cutting ring — a hardened bite-type sleeve whose edges cut into the tube OD as the nut tightens.
  • The series are wall-duty classes: LL is the very-light series (4–12 mm tube, up to about 100 bar), L is the light series (6–42 mm, up to about 315 bar on the smaller sizes), and S is the heavy series (6–38 mm, up to about 630 bar on the smaller sizes).
  • Ratings step down as tube OD grows within a series, and stainless assemblies may rate lower than the steel figures in the table — the manufacturer’s datasheet for the exact size governs.
  • Buyers searching “bite type” and “DIN 2353” are looking for the same parts; both phrases describe the 24° cone system on metric tube.

Which series do I need?

The series are wall-duty classes, not a quality ladder. LL suits light instrument duties such as lubrication and return lines, L covers general hydraulic and process runs, and S is for high-pressure working lines. Match the series to the tube OD and the line pressure, then confirm the rating on the datasheet.

Series Tube OD range Typical maximum working pressure What decides it
LL (very light) 4–12 mm Up to ~100 bar across the range The tube stays inside the 4–12 mm band and the duty is a light instrument line
L (light) 6–42 mm Up to ~315 bar at 6–18 mm; ~160 bar at 22 mm; ~100 bar at 28–42 mm Line pressure inside the L band and a general hydraulic or process run
S (heavy) 6–38 mm Up to ~630 bar at 6–14 mm; ~400 bar at 16–25 mm; ~315 bar at 30–38 mm Working pressure above the L band, so the wall-duty class has to step up

Read the table as ranges, not promises. A fitting’s rating depends on tube OD, wall, material and the exact fitting design, and it steps down within a series as the tube grows.

Stainless assemblies can rate below the steel figures shown in general catalogs. The governing number is the manufacturer’s rating for the exact size and material — request it on the datasheet with the quote.

What the table settles is the selection logic: LL for light instrument duties like lubrication and return lines, L for general hydraulic and process runs, S for high-pressure working lines, matched to metric tube from 6 mm upward. The fractional-versus-metric question is separate — see metric vs fractional tube sizes.

A printable version of this table lives on our DIN 2353 pressure chart sheet.

How does the 24-degree cone seal and grip?

Three parts do the work. The body carries a 24° cone seat machined into its bore. The cutting ring — the bite sleeve — sits between nut and body with two sharpened edges facing the tube.

As the nut tightens, the ring is driven forward and inward. Its front edge cuts into the tube’s outside surface, its back edge seats against the cone, and the ring deforms into a wedge that locks the tube against pressure.

Seal and grip form in one motion. There is no separate sealing washer and no thread sealant on the tube end. The mechanics match the ferrule in what is a ferrule fitting, with the cutting geometry doing the gripping.

How do I make up a joint without losing the bite?

The cut end and the state of the ring decide whether the joint holds. Work in this order.

  1. Cut the tube square.
  2. Deburr the tube end.
  3. Fit the nut and the cutting ring to the tube — ring between nut and body, sharpened edges facing the tube end.
  4. Seat the tube in the body and tighten: the front edge cuts into the tube and the back edge seats against the cone in the same motion.
  5. After the joint is opened, fit a new ring. A bitten ring is not re-bitten.

What goes wrong, and what do I change?

Most bite-type failures trace back to the tube end or the ring, not to the body. Find the symptom, then change the one thing that caused it.

Symptom Most likely cause What to change
Weeping at the cone after make-up Ring already bitten once and re-used Fit a new ring, re-make the joint
Tube pulls out under line pressure Tube end not cut square, or a burr left on the OD Recut square, deburr, new ring
Nut runs down without the ring biting Body and ring from a different series than the tube Match series and size — L and S of the same OD do not interchange
Assembly rates below the line pressure Stainless rating copied from a steel catalog figure Use the manufacturer’s datasheet rating for that size and material
Leak persists after sealant was added Sealant on the tube end, where the seal is on the 24° cone Strip the sealant, re-make with a new ring

None of these need a new body. The tube end and the ring carry most of the risk.

What goes on the order and the drawing?

State the series, the tube OD and the end form. The series call-out sets the pressure class and the nut geometry, the OD sets the body bore and the ring size, and the end form sets the port.

Two orders that read cleanly: “L-series bite-type union, 12 mm tube OD, both ends” or “S-series tube-to-male connector, 8 mm OD to 1/4 NPT”.

If the existing line carries no series marking, measure the tube OD and check the nut thread against the drawing before ordering. An L and an S fitting of the same tube size do not interchange.

Checklist before the RFQ goes out:

  • Series marked: LL, L or S
  • Tube OD in mm
  • End form and port thread
  • Material, with the rated pressure on the datasheet for that exact size
  • Body, ring and nut quoted as one matched set

FerruleX’s compression catalog is built on this DIN-style family for metric and fractional tube alike: compression fittings including the ground-finish tube-to-male connector for panel take-offs and the ground-finish straight union for line-to-line joints.

Where the run turns at the panel entry, the ground-finish male elbow; where the tube steps down, the ground-finish reducing union. Send series, tube OD and end form on the RFQ and we quote the body, ring and nut as a matched set. Request a factory quote.

Bite type or DIN 2353 — which name do I use?

Bite type describes what the cutting ring does. DIN 2353 names the standard that defines the 24° cone, the ring and the interchange dimensions. A buyer searching either phrase needs the same parts.

A drawing marked DIN 2353 accepts any manufacturer’s ring and body within the same series and size. That interchangeability is the point of the standard.

The standard also lives internationally. ISO 8434-1 absorbed DIN 2353’s 24-degree flareless connection dimensions, so a datasheet citing either points to the same interchangeable system.

FAQ

What is a bite-type fitting? A compression tube fitting to DIN 2353. It seals on a 24° internal cone and grips the tube with a cutting ring — a hardened sleeve whose edges bite into the tube OD as the nut tightens.

What are the LL, L and S series in DIN 2353? Three wall-duty classes for metric tube. LL takes 4–12 mm up to about 100 bar; L takes 6–42 mm and S 6–38 mm, up to about 315 and 630 bar on smaller sizes. Ratings step down as OD grows.

Are DIN 2353 pressure ratings fixed numbers? No. They vary with tube OD, wall, material and fitting design, and stainless assemblies can rate lower than steel. Treat published values as typical ranges and confirm the exact rating on the manufacturer’s datasheet.

Can I mix cutting rings and bodies from different makers? Yes — within limits. DIN 2353 defines the interchange dimensions, so same-series, same-size rings and bodies from different makers assemble together. Do not mix series or tube sizes: an L and an S of the same OD do not interchange.

Is a bite-type fitting the same as a DIN 2353 fitting? Yes. Bite type describes the cutting-ring action; DIN 2353 is the standard defining the 24° cone and the interchange dimensions. Both names point to the same compression system on metric tube.